Nm ≥ 60 & ALUMINIUM WHEEL
T5E-SP Hz : 9910004
T6E-SP Hz : 9910062
2
Wiring
You must have the possibility to switch off
individually each motor.
- Attach cables to prevent any contact with moving
parts.
- If the motor is used outdoors and if the power
supply cable is of the H05-VVF type, then run the
cable in a UV-resistant conduit, e.g. trunking.
3
Compatible transmitters
1: 1/5 channels Wall Hz transmitters / Memory Hz
2: 1/5 channels / SUN Mobile Hz transmitters
3: Color Multi 16 / Timer Easy / Timer Multi transmitters
4: Windy Hz Accel
5: EOSUN Hz VS
Location of the PROG key on Hz transmitters:
Do not position the transmitter near metal in order to
avoid range losses.
4
End-limit adjustement
If the installation includes several motors, only one motor is to be powered during this programming proce-
dure (4.1). It will eliminate interferences with the other motor during the procedure.
4.1- Learning mode:
- Switch the motor ON.
- Simultaneously press the "Up" and "Down" buttons of a Hz
transmitter. The motor will run for 0,5 second in one direction,
then in the other. The transmitter now controls the motor in
unstable mode, move to stage 4.2
4.2- Checking the rotation direction :
a
>>
b
Press the "Up" button of the transmitter:
a- If the motorized tube runs in the up direction, move to next stage (4.3).
b- If the motorized tube runs in the down direction, reverse the rotation direction by pressing the "Stop" button for at
least 3 seconds. The motor will run for 0,5 second in one direction, then in the other direction. Move to the stage 4.3.
2/6
5
STEEL
3
2
4
1
OK
4.3
>>
>>
>>
3s
N
L
PE
(12 transmitters max./3 sensors max. for one motor)
2
3
3
ON
>>
1
2
4
T5E-SP Hz / T6E-SP Hz
Blue
Brown
Green / yellow
4
5
4
5
>>
OK
4.3
>>
>>