13
Cancelling programming
13.1 - Switch off the power supply to the motor for 2 seconds.
13.2 - Switch the power to the motor back on for 7 seconds.
13.3 - Switch off the power supply to the motor for 2 seconds.
13.4 - Switch the power to the motor back on.
If the motor is on the end limit position (up or down), the motor will run
briefly on one direction and then in the other, otherwise, the motor runs
for 5 seconds in random direction.
The motor is now in the "cancelling" mode.
If you switch on/off the power to several motors, they will all be in the cancellation mode. That is why you must
eject out of this mode all the motors that are not to be deleted by sending a command from their individual control
transmitter (UP and DOWN).
13.5- Then, confirm the cancelling of the concerned motor
from the individual control:
- Press the "PROG" key of the transmitter more than 7
seconds. Maintain the pressure until the motor will first run for
a half a second in one direction and then the other, and a few
second later, it will run again in both direction.
i
The receiver is back in its original configuration. No more transmitters are programmed in the memory, start programming
again from section §4.1.The setting of functions « Back impulse», « Back release », « Closing force » are kept.
14
Operation and maintenance
- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
- If the motorised product is moving, briefly press the "Stop" button, the motorised product stop automatically.
- The motorised product is then stopped, briefly press the "Stop" button, the motorised product moves to the programmed
intermediate position. (To modify or delete an intermediate position, see the section §11).
Tips and recommendations for use:
PROBLEMS
The motorized product does not operate
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used
as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular of
the Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU declaration of conformity is available at www.simu.
com. Emmanuel CARMIER, general director, GRAY, 01/2017.
6/6
POSSIBLES CAUSES
The overheating protection on the drive has been
activated
OFF
ON
13.1
13.2
13.3
2s
7s
1
PROG > 7s.
Wait for the drive to cool down.
OFF
ON
13.4
2s
5s.
>>
2s.
7s.
SOLUTIONS