Menu Structure - Dimplex DHW 300D Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DHW 300D - DHW 300D+

7.2 Menu structure

Parameter change: The menu is accessed using the "Menu"
key. In this menu, changes can be made to parameters. The de-
sired menu item is selected with the arrow keys "UP" "DOWN".
The submenu is accessed using the "OK" key.
w
Menu block
Menu item
Settings
Time
Date
Language
Signal tone
Backlight
Factory setting
Type
Domestic hot
water
Set temperature
Lower
Hysteresis
Electric heater
Time programs
Therm. disinfection
1st lower
2nd lower
(only visible for devices with additional heat exchanger and OFF or Sol selected)
www.glendimplex.de
Parameter
Value
00:00
DD:MM:YYYY
DEUTSCH
ENGLISH
FRANCAIS
ITALIANO
POLSKI
0 % ... 50 % ...100 %
DHW 300
DHW 300+
DHW 300D
DHW 300D+
25 °C ... 45 °C ... 85 °C
15 °C ... 25 °C ... 40 °C
2 K ... 3 K ... 10 K
ECO
Mode
AUTO
Delay
Boost period
2 h ... 8 h...16 h
1 h ... 4 h ... 8 h
Boost set temp.
25 °C ... 60 °C ... 85 °C
Start
00:00 ... 23:59
Days
Mo ... Su
Set value
60 °C ... 65 °C ... 85 °C
Start
00:00 ... 23:59
End
00:00 ... 23:59
Days
Su ... Mo
Mo - Fr
Sa - Su
Mo - Su
Start
00:00 ... 23:59
End
00:00 ... 23:59
Days
Su ... Mo
Mo - Fr
Sa - Su
Mo - Su
451905.66.02a · FD 0102
In this submenu, the parameter that is to be changed can be se-
lected (also using the arrow keys). The "OK" key is used to se-
lect the marked value, which can then be changed via the arrow
keys. The entry is completed by pressing the "OK" key again.
Time setting (24 hour time display)
Date setting (Day:Month:Year)
Language selection
On
Setting key tone on / off
Off
Setting display backlight
Factory setting reset
Domestic water heat pump DHW 300
Domestic water heat pump DHW 300+
with additional heat exchanger
Domestic water heat pump DHW 300D
with defrost function
Domestic water heat pump DHW 300D+
with defrost function and additional heat exchanger
Sets the desired domestic hot water set temperature
Sets the minimum hot water temperature, which should also not be
undershot for the duration of a programmed lower process.
Sets the switching hysteresis
ECO: Only switches in the event of an error and with PV b./t., ther-
mal disinfection on
The electric heater is automatically switched on if the domestic hot
water set temperature is not reached within the set delay time in
heat pump operation.
Boost: adjustable time (once, regardless of the Auto/Eco setting)
Boost: adjustable set temperature
Thermal disinfection
Sets the start time for thermal disinfection (24 hour time display)
Sets the day on which thermal disinfection should be activated
Sets the set temperature for thermal disinfection.
Sets the start time for lowering the domestic hot water set temper-
ature
Sets the end time for lowering the domestic hot water set tempera-
ture
Sets the weekday / block of days on which the lower should be acti-
vated
Sets the start time for lowering the domestic hot water set temper-
ature
Sets the end time for lowering the domestic hot water set tempera-
ture
Sets the weekday / block of days on which the lower should be acti-
vated
English
Description
EN-9