Accuracy Control - Futech MEGACROSS Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

laser safety officer involvement,
protective clothes and eyewear,
special warning signs in the laser working area if used and operat-
ed as defined in this user manual due to the low eye hazard level.
Devices classified as laser class 2 or class 3R may cause dazzle,
flash blindness and afterimages, particularly under low ambient
light conditions.

ACCURACY CONTROL

Monitor horizontal levelling
1. Choose a room ±10 m long
2. Place the instrument next to wall no. 1.
3. Switch on the instrument and let it start levelling.
4. Mark the horizontal line in the middle of the cross on wall
no 1.
5. Turn the instrument through 180° and mark the laser beam in
the middle of the cross on wall no. 2.
6. Move the instrument as close as possible to wall no. 2.
7. Adjust the height of the laser so that the middle of the laser
cross is on the wall no. 2 marker.
8. Then turn the instrument through 180° and note the differ-
ence between the middle of the laser cross and the marker
on wall no. 1.
9. This difference should not exceed 3 mm.
10. NB: The tolerance depends on the distance of the walls
between which the inspection has been carried out. This dis-
tance should be multiplied by 2. Hence, if the instrument has
an accuracy of 3 mm / 10 m, then in our example the calcula-
tion is: 10 m distance x 2 = 20 m. Tolerance is 6 mm / 20 m.
Vertical laser line
Place the instrument approximately 5 m from a wall.
Place a 2 m long plumb-line against the wall.
Switch on the instrument and let it self-level.
Place the vertical laser line on the plumb-line.
This should be 1.5 mm in our example.