5
QS1
15 Amp
External short circuit
4
protection according
to local regulations.
P1
L´
L1
Main Supply Input
D
N´
200-240V, 50/60 Hz
N / L2
+/- 10%
PE´
PE
POWER ENTRY MODULE
(embedded Circuit Breaker TA35)
C
EMC
Z1
FILTER
A2
P24
Safe Torque Off
function
STO
DI3
B
DQ+
DQ-
Frequency Inverter
XPE3
Secotom-6...1100W
BASE
6
PLATE
CAUTION - Risk of electric shock.
Disconnect all power and wait 15 min.
before servicing
M1
Main AC Motor
3 x PT100
A
Secotom-6...750W
75
5
4
A1
Switchmode
Powersupply
A4
Control Board
24V-1
Isolation 3kVAC
(input/output)
24VDC
6,3A
PE
BASE
PLATE
Safety Standards:
UL508, EN50950-1
BASE
Class II
PLATE
Emergency Stop push buttom
XPE1
BASE PLATE
Door Guard
Lock
K3
4
3
YS1.4
SB1.1
Door Guard
Emergency Stop push buttom
Switch
(shown with
door open)
24V-2
24V-1: Unprotected voltage from 24VDC power supply
24V-2: Protected by Emergency Stop only
24V-3: Protected by Emergency Stop and Door switch
SB1.3
Emergency Stop push buttom
SB1.2
Magnetic switch
SS1.1
KS1
Safety relay
3
2
24V-3
K3
X5-1,2
S1
YS1.2
C
NO
S TRUE RS ApS
Pederstrupvej
DK -2750 Ballerup
Denmark
+45 44 600 800
Size
A 2
Scale
Friday, June 21, 2019
2
1
D
Door Guard
Lock
YS1
C
B
WATER PUMP
M2
A
84
Secotom - 6, Circuit Diagram
Safety Diagram
CA GE Code
DW G NO
Rev
16853101
C
Sheettt
3
3
EGA
of
1