Framing
•
Approved for combustible floor under and in front of
the appliance.
•
Combustible wall finish may contact the sides of the
heater's black frame.
•
Non-combustible wall finish may be required above the
heater, between the header and the backing plate—
see Wall Finish Detail & Mantel Clearances diagram.
Brackets on the rear of the backing plate to limit the
bottom height of:
•
the combustible wall finish
above the 534 heater,
or
•
the non-combustible
wall finish above the
535 heater.
Installation
1.
Install the heater into framed cavity as described in these instructions and com-
plete the remainder of the installation as per instructions packed with heater.
Finish the wall up to the perimeter of the black frame at the sides of the heater and
to the brackets on the rear of the backing plate, at the top. Ensure that the wall fin-
ish is flush or slightly in front of the black frame. Allow for height of finished hearth
or floor, or the steel backing plate will not install.
2.
Remove the existing top heat baffle supplied with the heater and replace it with
the heat baffle supplied with this kit using the same 3 screws. Ensure the baffle offsets upwards.
Note: Do not tighten the screws all the way as you will need to adjust the position of the baffle after the doors
are installed.
2
Combustible
mantel or
Framing Cavity
"A"
shelf
Wall Finish
Non-combustible
material above
535 model only
612 Backing Plate
"B"
31-3/4"
29-3/4"
Wall Finish Detail & Mantel Clearances
Mantel
2"
4"
6"
depth A
Mantel
32" 35" 38" 40" 42" 44"
height B
LH Frame
Header
36" from floor
to bottom
of header
Angle Support
Lower limit of
combustible
wall finish on 534
31-1/4"
from floor
534/535
Black Frame
8"
10" 12"