START UP
1. Connect the charger to the battery using the proper accessory (clamps, lugs, etc...).
2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz).
3. Select the mode by pressing the
4. During the charge, the device indicates the charge progress. When indicator
Once indicator
stays on, the battery is fully charged.
5. The charge can be interrupted at any time by unplugging the mains plug or pressing the
6. After the charge, disconnect the charger from the mains, then disconnect the clamps from the battery.
CHARGE MODES
• Modes and Options description :
Lead CHARGE mode (14.4 V/1 A) :
Mode for charging 12 V lead-acid batteries from 2 Ah to 32 Ah and up to 100 Ah for charge support.
Automatic seven step charge cycle.
Lithium CHARGE mode (14.4 V/1 A) :
Mode for charging 12 V lithium batteries from 0.5 Ah to 20 Ah and up to 50 Ah for charge retention.
Automatic charging cycle in eight steps.
• Load curve Lead:
The GYSflash 1.12 PL uses an advanced 7-step lead charging curve that guarantees the optimal performance of your lead battery.
1
U
I
Analysis
< 1s
CHARGE
OK
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion,
wrong battery...)
2
Step
: Recovery (0.5 A)
Recovering damaged elements due to a prolonged deep
discharge.
GYSFLASH 1.12 PL
button. After roughly five seconds, the charge starts automatically.
COLD/AGM option (14.7 V/1 A) :
Option to change the charging voltage to 14.7 V for battery charging in cold weather (less
than 5°C) or for some AGM batteries or batteries with plugs.
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which
disconnect the battery in case of deep discharge. This protection prevents the charger from
detecting the battery. In order for the Gysflash 1.12 PL to be able to charge the battery, it is
necessary to deactivate the UVP protection. To do this, select the Lithium charging mode and
press the button
and automatically start charging.
2
3
4
Recovery
Test
Desulfation
max 8h
< 1s
max 12h
blinks, the battery is ready to start the vehicle.
for 10 seconds. The charger will then deactivate the UVP protection
5
Charge
Absorption
max 25h
5
Step
: Charge (1 A)
Maximum current fast charge to reach an 80% charge level.
6
Step
: Absorption (14.4 V or 14.7 V with
Constant voltage charging to bring the charge level to 100%.
button.
6
7
Floating
charge
max 8h
no limit
AGM option)
EN