GYS FLASH 1.12 PL Mode D'emploi page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
3
Step
: Test
Sulfated battery test
4
Step
: Desulfation (15.8 V)
Battery desulfation algorithm.
• Lithium charging curve :
The GYSflash 1.12 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your LFP bat-
tery.
1
U
I
Analysis
< 1s
CHARGE
OK
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion, wrong battery...)
2
Step
: Recovery (0.2 A)
Recovery algorithm following a deep discharge.
3
Step
: Charge (1 A)
Fast charging at maximum current allowing to reach 90% of the charge level.
4
Step
: Absorption (13.8 V)
Constant voltage charging to bring the charge level to 98%.
• Estimated charge time
Battery capacity
Charging time
0% >> 90%
*Lead battery equivalent: A lithium battery has better starting performance (CCA) than a lead battery. This is why some lithium
battery manufacturers indicate the battery lead equivalent (EqPb) corresponding to the capacity of a lead-acid battery with the
same starting performance. For instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid battery of
around 30 Ah.
If the motorcycle is equipped with a 12 V socket, the GYSFLASH 1.12 PL is able to charge the battery via this socket
with the CAN-BUS system, without having to switch on the instrument panel. In this setup, connect the cigratte lighter
adapter (ref. 029439) on the charger and the 12 V socket of the motorcycle and then follow the «Start-up» procedure
detailed above. In certain cases, it is possible that the charge will only start 2 minutes after performing the connec-
tions.
10
GYSFLASH 1.12 PL
2
3
Recovery
Charge
Absorption
Max 5 min
Max 30 h
Lead-acid
2 Ah
10 Ah
2 h
9 h
7
Step
: Floating charge (13.6 V)
Maintains battery charge level at its maximum.
4
5
6
Equalizing Battery System
Test
Supplement
Max 20 h
3 min
Max 10 h
Step
Charge conservation test.
Step
Reduce current charge to reach 100% charge
level.
Step
Balancing the battery cells
Step
Maintain the battery charge level at its maximum
with maintenance charging every 10 days.
1 Ah
20 Ah
32 Ah
(3 Ah EqPb*)
18 h
29 h
1 h 30
7
8
Equalization /
Floating charge
balancing
Max 2 h
No limit
(maintenance every 10 days)
5
: Test
6
: Supplement
7
: Equalization / balancing (14.4 V)
8
: Floating charge (13.8 V)
Lithium
5 Ah
10 Ah
(15 Ah EqPb*)
(30 Ah EqPb*)
4 h 30
8 h 30
EN
20 Ah
(60 Ah EqPb*)
16 h

Publicité

Table des Matières
loading

Table des Matières