GYS FLASH 18.12 PL Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
• Lithium charging curve :
The GYSflash 18.12 PL uses a 8 steps charging curve which guarantees optimal performance for your LFP battery.
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion, wrong battery...)
2
Step
: Recovery (
Recovering damaged elements due to a prolonged deep discharge.
3
Step
: Charge (
Maximum current fast charge to reach 90% charge level.
4
Step
: Absorption (13.8 V)
Constant voltage charge to reach 98% charge level.
• Estimated charge time :
Charging current
Battery capacity
Charge timing
0% >>> 90%
• Protections :
The GYSFLASH 18.12 PL has comprehensive safety features to protect it against short-circuits and polarity reversals.
It has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has
double insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 18.12 PL is fitted with an integrated temperature sensor that ensures that the charging current is adapted to the
ambient temperature to prevent internal the electronics from overheating.
12
12
GYSFLASH 18.12 PL
- 1 A /
- 1.6 A /
- 7A /
- 12A /
Lead-acid
15 Ah 50 Ah 50 Ah
80 Ah
2 h
7 h
4 h
6 h
- 1.8 A)
- 18A)
80 Ah
130 Ah
270 Ah
4 h
7 h
14 h
5
Step
: Test
Charge conservation test.
6
Step
: Supplement
Reduce current charge to reach 100% charge
level.
7
Step
: Equalizing / balancing (14.4 V)
Balancing of battery cells.
8
Step
: Floating charge (13.8 V)
Maintains battery charge level at its maximum
and goes through charge maintenance cycle
every 10 days.
Lithium
7 Ah 12 Ah 12 Ah 20 Ah 20 Ah 130 Ah 270 Ah
1h
2h
1h
2h
EN
1h
7h
14h

Publicité