CIRCLE FILTRATION SYSTEM PERFORMANCE DATA SHEET
The RC100 is tested and certified to NSF/ANSI 42, 53 and 58 for the reduction of Aesthetic Chlorine,
Taste and Odor, Cyst, VOCs, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium,
Hexavalent Chromium, Trivalent Chromium, Lead, Copper, Selenium and TDS as verified and
substantiated by test data. The RC100 conforms to NSF/ANSI 372 for low lead compliance.
This system has been tested according to NSF/ANSI 42, 53 and 58 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible for water leaving the system, as
specified in NSF/ANSI 42, 53 and 58.
Substance
Arsenic (Pentavalent)
Barium
Radium 226/228
Cadmium
Chromium (Hexavalent)
Chromium (Trivalent)
Copper
Lead
Selenium
Fluoride
TDS
Aesthetic Chlorine
VOCs
While testing was performed under laboratory conditions, actual performance may vary.

GENERAL OPERATING INFORMATION

Rated Capacity
Min-Max operating pressure:
Min-Max feed water temperature:
Rated Service Flow
Daily Water Production Rate
Product Efficiency Rating
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Refer to the owners manual for specific installation instructions, manufacturer's limited warranty, user
responsibility, and parts and service availability.
The influent water to the system shall include the following characteristics:
No organic solvents
Chlorine: < 2 mg/L
pH: 7 - 8
Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
22
Influent Challenge
Maximum Allowable Product
Concentration
(mg/L unless specified)
0.05 +/- 10%
10.0 +/- 10%
25 pCi/L
0.03 +/- 10%
0.3 +/- 10%
0.3 +/- 10%
3.0 +/- 10%
0.15 +/- 10%
0.10 +/- 10%
8.0 +/- 10%
750 +/- 40
2.0 +/- 10 %
0.300 +/- 10%
3,500 gal. for Aesthetic Chlorine / 243 gal. for VOC's
Model: RC100
Water Concentration
(mg/L unless specified)
0.01
2
5 pCi/L
0.005
0.1
0.1
1.3
0.01
0.05
1.5
187
>/= 50% Reduction
>/= 95% Reduction
40psi-120psi (275Kpa-827Kpa)
41°F – 95°F (5°C – 35°C)
0.07 gallons per minute
56.9 gallons per day
30.6%
Iron: < 2 mg/L
Turbidity: < 1 NTU
Hardness: < 1 000 mg/L
Percent Reduction
(%)
98.9
98.2
80
98.2
97.3
97.8
98.7
98.2
97.3
83.8
92.5
98.4
99.8