Water Filtration System Performance Data Sheet
Brand: H
0+
2
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below . The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53 .
Substance
Chlorine, Taste, & Odor
NSF/ANSI 42
Particulate Class 1
Aesthetic Effects
particles 0 .5 to < 1µm
NSF/ANSI 53
Health Effects
While testing was performed under laboratory conditions, actual performance may vary .

General Operating Information:

Rated Capacity
Min-Max operating pressure:
Min-Max feed water temperature:
Rated Service Flow
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system .
• Refer to the owners manual for specific installation instructions, manufacturer's limited warranty, user
responsibility, and parts and service availability .
• For parts and service availability, please contact Brondell .
• The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee
period, but it means the ideal time of filter replacement . Accordingly, the estimated time of filter replacement
may be shortened in case it is used in an area of poor water quality .
Model of Replacement Filter
HF-25
Brondell, Inc.
PO Box 470085
San Francisco, CA 94147-0085
Phone:
1-888-542-3355
Email:
support@brondell.com
Web:
www.brondell.com
Average Percent
Reduction
98 .0%
91 .3%
VOC's
99 .8%
Type
CARBON BLOCK FILTER
Influent Challenge
Concentration (mg/L
unless specififed)
2 .00 ± 10%
at least 10,000
particles/mL
3 .00 ± 10%
5,000 gal . for Aesthetic Chlorine / 150 gal . for VOC's
10 psi – 58 psi (0 .07 MPa – 0 .4 MPa)
41 ºF – 95 ºF (5 ºC – 35 ºC)
0 .50 gpm
Usable period (months)
Model: H625
Maximum Permissible
Product Water
Concentration or
Minimum Allowable %
Reduction (mg/L unless
specififed)
≥ 50% Reduction
≥ 85% Reduction
≥ 95% Reduction
6