Fuel Consumption; Natural Gas - Briggs & Stratton 45000 Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

When the initial test runs are completed, the manometer
is removed and the port is plugged. A typical final fuel
connection assembly is shown here, where (A) is the fuel
supply and (B) goes to the home generator.
A
Fuel Pipe Sizing
There are numerous on-line or otherwise-published
references for fuel pipe sizing. The installer should consider
the specific gravity of gas and compensate for a nominal
amount of restriction from bends, fittings, etc. If an unusual
number of fittings, bends, or other restrictions are used,
please refer to federal and local codes.
12
B

Fuel Consumption

Estimated fuel supply requirements at half and full load for
natural gas and LP vapor fuels are shown below.

Natural Gas

1/2 Load
Full Load
45kW
483 C
777 C
483,000 B 777,000 B 445,000 B 742,000 B
C = Cubic feet per hour
B = BTU's per hour
Physical Properties
Normal Atmospheric State
Boiling Point (in °F):
Initial
End
Heating Value:
BTU per gallon (Net LHV*)
BTU per gallon (gross**)
Cubic feet (gas)
Density***
Weight†
Octane Number:
Research
Motor
*
LHV (Low Heat Value) is the more realistic rating.
**
Gross heat value does not consider heat lost in the form of water
during combustion.
*** Density is given in "Cubic Feet of Gas per Gallon of Liquid".
Weight is given in "Pounds per Gallon of Liquid".
LP Vapor
1/2 Load
Full Load
178 C
297 C
LP Vapor
Natural
Gas
Gas
Gas
-44
-259
-44
-259
83,340
63,310
91,547
2,500
1,000
36.39
57.75
4.24
2.65
110+
110+
97
BRIGGSandSTRATTON.COM

Publicité

Table des Matières
loading

Table des Matières