Put the motor on the pump and tighten the
union nut (5).
>
Connect the motor to the power supply.
Use with spring balancer:
>
At heavy three-phase motors (> 10 kg) mount
the bracket (7) (accessory) on the bearing
flange (6) of the eccentric worm-drive pump.
>
To handle the three-phase motor with the
pump, a spring balancer must be mounted
onto the bracket (7) of the motor.
Before installation and commissioning, carry out a visual inspection of the drum emptying
system and the hoses.
Attention!
> Observe the maximum permitted operating pressure of the hose.
Allow for sufficient nominal diameter.
> Keep the hose as short as possible.
In order to relieve the drum emptying system from the weight of the hose
filled with the medium, we recommend using a spring balancer.