Torqeedo Power 48-5000 Traduction De La Notice D'emploi Originale page 56

Masquer les pouces Voir aussi pour Power 48-5000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DE
EN
FR
Defects (red)
Defects cannot be remedied by the user. Torqeedo Service must be contacted in the
event of a defect.
Possible causes:
Battery deep-discharged
Irreversible self-protection triggered
Electronics self-check failed
Errors (red)
Errors lead to automatic power-off of the voltage outputs. These errors can be reme-
died. After remedying the errors, you can again attempt to switch on the Power
48-5000. The Power 48-5000 does not automatically switch on.
If the Power 48-5000 has automatically powered off the voltage outputs, yet it is still
switched on (at the switch), the internal electronics (and thus also the communica-
tion and LED) will switch off after one hour.
Possible cause of error
Temperature too high
Temperature too low
Short circuit or overcurrent detected
The system Emergency kill switch/
Emergency Off switch has been
pushed
page 56 / 104
Troubleshooting
Let battery cool down
Provide for long-term cooling if
necessary
Operate battery within the speci-
fied temperatures
Check wiring
Check whether power consump-
tion by connected loads is too
high
Remote accelerator lever at stop
Deactivate Emergency kill switch
Switch battery on again
Warnings (yellow)
Warnings are notifications to the user. They will not cause the battery to automati-
cally switch off. An exception is SOC 0%.
LED display