CHANGING THE SUPERCODE
The new code should consist of 6 characters and
must not match the stores access codes, even
partially.
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter the code B4
» the green LED
flashes
3.
Enter a new supercode (example: 578661)
During entry, the green LED
» if the code is correct: the LED
for 3 seconds
» if the code is rejected: the LED
for 3 seconds
4.
Press
twice to exit programming
mode
RESTORE FACTORY SETTINGS
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter the initialising code BA0BAB
» the number keypad restarts, wait 20 seconds.
PERMANENT ACTIVATION OF THE
NUMBER KEYPAD MODULE BACKLIGHT IN
STAND-ALONE MODE
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter code B0
3.
Enter the programming sequence
4.
Press
twice to exit programming
mode
The keypad has several advanced functions as
described in the full manual, which is available to
download from the website pro.comelitgroup.com
Programming via ViP Manager
The ViP Manager software used to program the
number keypad module using a computer is available
on the website pro.comelitgroup.com.
77889
The main functions available are as follows:
• Access code entry. The access codes may be Permanent
• Each access code can be assigned up to 4 different actions
(code)
flashes.
• Call code entry. The call function is enabled by default. It
lights up in green
• Activation of playback of the relevant audio message
lights up in red
• Event log complete with all information (activated codes,
2 ×
• "Trade" function. On specific days of the week and in
77889
AVAILABLE CONNECTIONS
BA0BAB
77889
520330090
2 ×
Search for devices to configure (fig. page 41)
√ Connect the number keypad to the computer
In Options (1) / Local connections (2), select
thenetwork interface (3).
Confirm by clicking OK (4).
Click Scan system (5) to start searching for devices.
Populating the contacts list (fig. page 41)
1.
2.
3.
(always valid), metered (valid for a certain number of uses) or
associated with a validity date. In the latter case, each code
can be assigned a validity start/end date, dual daily time
band and validity days.
which will be carried out consecutively.
can be disabled.
when each button is pressed (e.g. if you press 2 on the
number keypad, audio message "two" will be played).
user that used them, users called, etc.). Up to 1275 events
can be saved in the memory.
specific time bands, simply pressing the key button (without
entering any code) will activate the output associated with the
keypad without an external clock.
1440
and open ViP Manager
Select Contacts/Name addressbook
Enter the information required (for each contact
you need to enter at least one "access code";
enter the "Name" if you want to pair actions)
Press "Write page" to send the data to the