Programming via number keypad
CHANGING RELAY SETTINGS
By default:
• the relay activated when a valid access code is
recognised is the SE output for the audio or audio/
video module
• the access codes are set as permanent
If the number keypad module is in stand-alone
mode, or if you want to change these parameters,
you will need to follow the procedure below before
creating the access code.
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter B5
3.
Enter the number corresponding to the
output you want to activate
1 = keypad relay 1
2 = keypad relay 2
3 = keypad relay 1 and relay 2
4 = audio or audio/video module SE output (default)
5 = audio or audio/video module relay 1
6 = external actuator
4.
If you selected "6 = External actuator"
in step 3, enter the actuator address;
otherwise press 0
The actuator address must consist of 3 digits,
followed by 5 zeros!
For example: address 5, enter 00500000
For example: address 23, enter 02300000
For example: address 132, enter 13200000
5.
Set
the
opening
0 = permanent (default): the access code
is always valid.
N [1 – 9] = limit the number of code entries
Example: if you select "5", the code can be used 5
times, after which it will be deleted
6.
Press
twice to exit programming
mode
From this moment on, all new stored access codes
will activate the configured output and will possess
the new set validity.
The activated output and the validity of the access
codes stored previously will remain unchanged.
CREATING AN ACCESS CODE
The default output activated by the access codes is
the SE output for the audio or audio/video module.
If you want to change it, you must follow the
procedure
described
"Changing relay settings" BEFORE creating
the access codes.
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
18
77889
(number)
(address)
code
validity.
(number
of uses)
2 ×
in
the
section
77889
2.
Enter a valid access code (example:
98654)
the following are not permitted:
• codes shorter than the number of characters
required for access codes
• codes matching the supercode (even partially)
• codes matching the universal code
• codes containing the characters A or B.
3.
Confirm by pressing B
» if the code is correct, LED
3 seconds
» if the code is rejected, LED
3 seconds
4.
Wait for the LED
to turn yellow and repeat steps
2 and 3 to enter other access codes
5.
Press
twice to exit programming
mode
USING AN ACCESS CODE
Enter the programmed access code (example:
98654) to activate the paired relay
» if the code is correct: the output is activated and the LED
lights up in green for 3 seconds
» if the code is incorrect: the LED
3 seconds
» if the maximum number of incorrect code entry attempts
is reached, the keypad locks for 15 seconds and the red
LED
flashes for the duration of the lock period.
DELETING AN ACCESS CODE
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter the access code you want to
delete (example: 98654)
3.
Confirm by pressing A
4.
Wait for the green LED
5.
Press
twice to exit programming
mode
DELETING ALL ACCESS CODES
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter the code BA0ABA
» the number keypad restarts, wait 20 seconds.
USE AS A CALL MODULE
1.
Enter the code for the internal unit you
want to call (example: 1) During entry,
» the green LED
flashes
2.
Confirm by pressing B
» a call sent confirmation tone sounds
The code can consist of up to 3 digits.
(code)
(default 5)
lights up in green for
lights up in red for
2 ×
(code)
lights up in red for
77889
(code)
to turn yellow
2 ×
77889
BA0ABA
(code)