Skandika Fitness CARDIOCROSS CARBON PRO Instructions De Montage page 51

Masquer les pouces Voir aussi pour CARDIOCROSS CARBON PRO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
Possible Cause
The speed display
The computer does not
shows 0.
receive any signal from
the speed sensor.
The sensor is defective.
The computer is defective Contact your dealer and replace the computer.
The LCD screen
The connection
shows partial
between PCB and the
display.
screen membrane is
loose. Press the screen
gently – if the display
disappears, it is a con-
nection problem.
The connection bet-
ween PCB and LCD
screen is aligned incor-
rectly. The LCD screen
is perhaps inclined or
not parallel to the com-
puter housing.
The computer is defective Contact your dealer and replace the computer.
In case of mechanical problems of any nature, please use the following exploded assembly drawing.
Here, all the parts are represented with a specific number. If needed, please mention this number to
replace the part free of charge in the course of guarantee period. Even the shipping costs are borne
by Skandika.
Solution
1. Check whether the sensor magnet is assembled correctly and is in front of the sensor.
2. Check whether the distance between the magnet and sensor (correct==5 mm or less)
3. Check whether all the plugs and jacks are connected correctly and firmly.
4. Check whether the cables are intact.
If these checks are not successful, replace the sensor.
Check whether the PCB is connected firmly with the computer housing. Tighten the screw properly
but not very tight.
Open the computer housing, remove the PCB screws, remove the PCB carefully, align the LCD
screen or the membrane correctly and assemble the parts.