Technical Data - Hilti C 6-22 Mode D'emploi Original

Masquer les pouces Voir aussi pour C 6-22:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

Technical data

Weight in accordance with
EPTA Procedure 01
Rated output voltage
Maximum output power
Storage temperature
Ambient temperature for
operation
5
Operation
WARNING
A damaged supply cord presents a hazard! If the supply cord or extension
cord is damaged while work is in progress, immediately disconnect the
product and the cord from the electricity supply. Do not touch the damaged
part of the cord!
▶ Regularly check all supply cords.
▶ Replace defective extension cords.
▶ Otherwise, contact Hilti Service.
Use of a ground fault circuit interrupter (residual current device, RCD) with a
maximum tripping current of 30 mA is recommended.
5.1 Switching on charger and charging battery
WARNING
Explosion hazard if any attempt is made to charge unapproved batteries.
Injuries and damage to the charger can result.
▶ Do not attempt to charge non-rechargeable batteries.
▶ Use only Hilti-approved batteries with this charger.
CAUTION
Short-circuit due to moisture or dampness Damage to the product is the
result.
▶ Use the product only indoors.
▶ Keep the product away from moisture and dampness.
1. Plug the supply cord into the power outlet.
▶ The LED shows green.
2. Engage the battery on the battery interface.
▶ The battery is charging.
3. When the battery is fully charged, remove it from the charger.
*2275225*
C 6-22
0.84 kg
(1.85 lb)
10.8 V ... 21.6 V
240 W
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
2275225
English
7

Publicité

Table des Matières
loading