Emerson DESIGNER CF755GRT06 Mode D'emploi page 6

Ventilateur de plafond de 52 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Ceiling Fan Assembly
3.3
Loosen the Two Upper Phillips Head Set Screws
in the Motor Coupler for installation of the Downrod
(Figure 3).
Seat the Downrod in the Motor Coupler (Figure 3).
Rotate and align the Downrod Holes with the Two
Holes in the Motor Coupler (Figure 3).
3.4
Align the Clevis Pin holes in the Downrod with the
Holes in the Motor Coupler.
Install the Clevis Pin and secure with the Hairpin Clip
(Figure 4).
The Clevis Pin must go through the holes in the Motor
Coupler. It is critical that the Clevis Pin in the Motor
Coupler is properly installed and securely tightened.
WARNING
It is critical that the clevis pin in the motor coupler
is properly installed. Failure to verify that the pin is
properly installed could result in the fan falling.
3.5
While pulling up on the Downrod, retighten the Two
Upper Phillips Head Set Screws to secure the Downrod
in the Motor Coupler (Figure 5).
NOTE: The Set Screws must be properly installed
as described above, or fan wobble could result.
WARNING
It is critical that the set screws in the motor coupler are
properly installed and securely tightened. Failure to
verify that the set screws are properly installed could
result in the fan falling.
(Continued)
3.5" DOWNROD
LOOSEN
PHILLIPS HEAD
UPPER
SET SCREWS (2)
3.5" DOWNROD
MOTOR COUPLER
CLEVIS
PIN
3.5" DOWNROD
RETIGHTEN
UPPER PHILLIPS HEAD
SET SCREWS (2)
Figure 5
6
HAIRPIN
CLIP
CLEVIS
PIN
HAIRPIN CLIP
MOTOR COUPLER
U.L. Model No.: CF755

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Designer cf755orb06Designer cf755ww06

Table des Matières