Horizontal levelling and vertical levelling
– Horizontal: Position the device on a level surface or
on a tripod.
– Vertical: Set the unit on its side feet. The operator
panel should be at the top. With the optional wall
bracket (product ref. 080.70), the device can be
mounted on a tripod for vertical usage.
– Press the "ON/OFF" switch
!
auto/man function LED OFF: Automatic alignment
– The device levels itself automatically to within a range of ± 5°. During the
set-up phase, the laser flashes and the prism head remains stationary. When
levelling is complete, the laser lights up continuously and rotates at maxi-
mum speed. Refer also to the sections about "Sensor Automatic" and "ADS
Tilt".
If the device has been placed on a surface with too much of a slope
!
(more than 5°), there is a warning sound, the prism head remains
stationary and the laser starts to flash. The device must then be
placed on a more even surface.
Positioning the vertical laser level
In vertical mode the laser level can be positioned exactly. "Sensor Automatic"
remains active and levels to the vertical laser level. Refer to the illustration
below.
If the auto/man LED flashes, the maximum adjustment range of 5° has
!
been reached. Set up the device horizontally, turn it off and then on
again.