Safety Precautions

• Read the Installation Instruction and Maintenance
Owner's Manual before installing.
• Follow all local codes for installation.
• To reduce the risk of electric shock, connect only to
a properly grounded, ground fault interrupter (GFI).
• Do not immerse the IonGen
in water.
GROUNDING INSTRUCTIONS: This appliance must be
grounded. In the event of a malfunction or breakdown,
grounding will reduce the risk of electric shock by
providing a path of least resistance for electric current. This
appliance is equipped with a cord having an appliance-grounding
conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper connection of the appliance-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service representative if you are in doubt
whether the appliance is properly grounded. Do not modify the
plug provided with the appliance; if it will not fit the outlet, have
a proper outlet installed by a qualified technician.
IonGen
System Specifications
• Input Voltage: 120 Volts
• Input Frequency: 60 Hz
• Output Voltage: 12 V
• Output Current: 0.5A
• Plug-in Transformer: UL Listed, CSA Listed
Rainproof Class 2
• Flow Chamber: Injection Molded Plastic
• Probe Material: 99% Copper
• Capacity: Up to 25,000 gallon water features
Installation for the Aquascape IonGen
IMPORTANT: Before installing the IonGen
in existing water features it is recommended to
thoroughly clean the pond of as much debris as
possible. This will maximize the ions' effectiveness and speed
to achieve desired results. The more debris in the water feature,
the longer it will take the Aquascape IonGen
noticeable results.
4
System Control Panel
System
System
System to provide
US 1-866-877-6637 |
1. Mount the IonGen
System Control Panel
Mount the IonGen
System Control Panel
in the desired location;
making sure the power
cord reaches the GFI
outlet and the IonGen
Probe cord reaches
the desired location of the IonGen
Cable with Quick Connects (sold separately) is available, if
needed. The IonGen
System Control Panel
is weather-resistant, but in order to maximize the lifespan
of your unit, we suggest mounting the panel above ground
in a location protected from the elements.
2. Install the Flow Chamber
The Flow Chamber for the IonGen
in several areas within the water feature. The Flow Chamber
is most effective when plumbed directly into the water
feature's recirculating system. The IonGen
be installed without the Flow Chamber by submerging it in
a filter, such as in a skimmer or Pondless
Follow the step-by-step installation instructions for the
method you select.
Installation Option A:
Flow Chamber Installed into Recirculating System
• Cut and insert the Flow
Chamber into the water
feature's recirculating
system. The Flow Chamber
should be positioned after
the water feature's pump,
and in a region of the
plumbing line that drains
by gravity. This is enables
you to easily service the
IonGen
Probe and allows
for overwintering the Flow
Chamber and fittings. It is
recommended to use a pre-
filter, such as a skimmer,
prior to the Flow Chamber,
in order to remove solids
and debris that may
interfere with the IonGen
Probe. A small valve box may be used for easy access
during maintenance.
• Select the fittings needed for the application. The PVC slip
fitting is designed to be used with Schd 40 PVC pipe (Rigid
or Flex) and PVC glue. The multi-hose adapter fitting is
designed to be used with kink-free pipe and hose clamps.
Refer to page 3 for adapters and fittings.
CAN 1-866-766-3426 | www.aquascapeinc.com
Probe. A 25' Extension
System can be located
Probe can also
®
Waterfall filter.