• If using a diameter pipe larger than the smaller hose tails,
cut off the hose tails not being used with a hack saw in
order to maximize the water flow through the plumbing.
• When using the Barbed
Multi-Hose Fitting, use a
metal hose clamp to secure
pipe to fitting.
• When using PVC, glue pipe into Slip Fitting using PVC glue
(not included). Follow the glue manufacturer's directions for
proper plumbing steps.
• Install the IonGen
Probe into the top of Flow Chamber.
• Insert IonGen
Probe
cord through the IonGen
Probe collar.
www.aquascapeinc.com |
• Hand thread the selected
fitting into the Flow
Chamber. (Do not use tools
to install the fittings into
the Flow Chamber. Fittings
need to be hand-tight only.)
• Hand-tighten the IonGen
Probe collar into position.
CAN 1-866-766-3426 |
Installation Option B:
IonGen
Probe only using IonGen
The IonGen
Probe can also be submerged in a filter by using
the IonGen
Probe Holder.
1. Position the probe holder bracket in the desired location on
check valve or plumbing.
2. Pull the buckle securely fastening the probe holder in place.
3. Trim away remaining or excess strap if necessary.
4. Position the IonGen
PLEASE NOTE: The IonGen Probe must be fully
submersed in water at all times to function properly.
Failure to provide sufficient water flow across IonGen™
Probe will affect the IonGen™ System's performance.
See troubleshooting Table for more information.
Operating Instructions
• Before using the IonGen
– The IonGen
System may be used in ponds or fountains
containing fish as long as the copper concentration is
carefully monitored and the concentration is not allowed to
exceed 0.25 ppm.
– If the total alkalinity of the water is less than 100 ppm,
you'll need to increase the level of alkalinity. Do not operate
the IonGen
System on water features with fish if the
alkalinity levels are below 100 ppm.
– If the total alkalinity of the water is above 250 ppm you will
need to decrease the level of alkalinity. If alkalinity is more
than 250 ppm it can be typically reduced by conducting a
partial water change. Check to make sure your tap water
is within the target water parameters.
– Alkalinity (not hardness) can be determined using the KH/
Alkalinity Test Kit (part #96019). Alkalinity levels outside
of the recommended parameters will significantly reduce
and possibly eliminate the effectiveness of the IonGen
System.
See Targeted Water Parameters section for
more information.
US 1-866-877-6637
• Plug the connector from
the Control Panel into
the IonGen
Probe
fitting connector.
Probe Holder
Probe into the Probe Holder.
System, please note the following:
5