12. The Lead program group

Lead-acid batteries should always be charged at the normal charge current. The "normal"
current is deemed to be 1/10 of the nominal battery capacity.
This program group includes the following functions / menus:
Charging Pb batteries:
Final charge voltage, Pb: 2.333 V per cell
o
Variable charge current
o
Variable nominal voltage
o
Discharging Pb batteries:
Final discharge voltage, Pb: 1.800 V per cell
o
Variable discharge current
o
Variable nominal voltage
o

12.1. Charging lead-acid batteries

Pb CHARGE
C=0.1A
2Vpack
ENTER
DEC
Pb CHARGE
C=2.5A
2Vpack
ENTER
DEC
Pb CHARGE
C=2.5A
8Vpack
START
BATTERY CHECK
WAIT PLEASE...
CHG
0:00
00000
PB+2.50A
7.865V
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten • www.multiplex-rc.de
MULTIcharger LN-6015 EQU Operating Instructions

the Pb CHARGE menu

INC
Press the INC button to move to the Pb DISCHARGE menu.
INC
Pressing the ENTER button takes you to setting the charge current. You
can increase this value by pressing the INC button, or reduce it by
pressing the DEC button.
INC
Pressing the ENTER button takes you to setting the nominal voltage.
You can increase this value by pressing the INC button, or reduce it by
pressing the DEC button.
Hold the START button pressed in to initiate the charge process. You
can interrupt the charge process at any time by pressing the STOP
button.
The MULTIcharger LN-6015 EQU now checks whether the battery is
connected correctly. If all is well, the charger initiates the charge
process.