WARNING
Incorrect mounting at Zone 0
Danger of explosion in hazardous areas.
Ensure sufficient tightness at the process connection.
Observe the standard IEC/EN 60079-14.
CAUTION
External stresses and loads
Damage to device by severe external stresses and loads (e.g. thermal expansion or pipe tension). Process media can be
released.
Prevent severe external stresses and loads from acting on the device.
4.1.2
Installation and location requirements
CAUTION
High vibration area
Especially with the stainless steel housing version of TS500, use short extensions or external supports when used in a high
vibration area.
When TS100/200 sensors are installed in a high vibrating area, use also external supports to fix the probe stem: the
unsupported length must not exceed 150 mm and the free end must not exceed 100 mm.
CAUTION
Direct sunlight
Device damage.
The device can overheat or materials become brittle due to UV exposure.
Protect the device from direct sunlight.
Make sure that the maximum permissible ambient temperature is not exceeded. Refer to the information in Technical
data (Page 23).
4.1.3
Proper mounting
NOTICE
Incorrect mounting
The device can be damaged, destroyed, or its functionality impaired through improper mounting.
Before installing ensure there is no visible damage to the device.
Make sure that process connectors are clean, and suitable gaskets and glands are used.
Mount the device using suitable tools. Refer to the information in Technical data (Page 23) for installation torque
requirements.
Note
Loss of degree of protection
Damage to device if the enclosure is open or not properly closed. The degree of protection specified on the nameplate is no
longer guaranteed.
CAUTION
Loss of IP protection
Do not unscrew the device housing from the mounted parts with NPT threaded connection