MANUAL MODE
To access this mode, press the button «MODE» of the GYSDUCTION AUTO until the LED «MANUAL» switches on.
The manual mode allows the user to set the desired heating power (0 to 100%).
At a 100%, the delivered power is 1.2 kW.
To start the heating, the inductor's button or foot pedal must be pressed. To stop the heating, release the button or the
foot pedal.
This mode is recommended for small pieces, or when using the flexible wire.
AUTOMATIC MODE
To access this mode, press the button «MODE» of the GYSDUCTION AUTO until the LED «AUTO» switches on.
To maintain a constant optimal heating power, the machine adapts, in Auto mode, to the workpiece (size) and to the
distance between the coil and the workpiece.
To start the heating, the GYSDUCTION's button or foot pedal must be pressed.
Warning : it starts when there is enough metal within the coil.
It stops when the user releases the button or the foot pedal.
RECOMMENDATIONS
• When heating the coils for the first time, some smoke will be released.
• Avoid heating for more than 30s, the coils will heat excessively and suffer premature damages.
• It is not necessary to come in contact with the bolt to heat it.
• The coil's protective fabric is fragile, it is glass fabric : make sure to store the coils in such a way that they do not
get damaged.
The coils heat very fast. After use, is is recommended to let them cool down before storing them. Ma-
nipulate with gloves to prevent burns or itches caused by the glass fabric.
Do not place a finger or any limb inside or close to the coil when the machine is switched on. Magnetic
fields should be considered.
SPECIFICATIONS
Induction heating machine dimensions (L x w x h)
Inductor weight only
Cable length
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
• Inductors and removable ferrites that are consumables.
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
14
COILED INDUCTOR
330 x 70 x 90 mm
1.7 kg
2.40 m
EN