GYS 054783 Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
COILED INDUCTOR
EN
3
2
4
1
fig.1
The elements contained in this carry case are fragile. They're to be handled with care.
STARTING
Assembly
Choose the required tool (one of the 3 coiled wires, the braided wire or the straight wire) and fit it on the inductor. To
do so, insert the two rods of the selected tool and insert them into the holes intended for this purpose, then screw the
tightening wheels (fig.2). To unscrew a tightening wheel, it is possible to use a spanner/wrench size 12. Warning :
never use a spanner/wrench to screw the tightening wheel as it may get damaged.
Connection
The coiled inductor is designed to be conected to the GYSDUCTION AUTO. When switched on, the machine identifies it
as accessory n°5 : «AC5».
Heating activation
Two controls maybe used to activate the heat :
- the button on the inductor
- the foot pedal supplied with the GYSDUCTION AUTO.
RECOMMENDATIONS
The coiled inductor is designed for unjamming. it heats metal pieces or parts via induction to unblock and remove them
easily. Circle the piece using the appropriate accessory (coiled, braided, straight), then heat the inductor, that will be
used to heat the metal piece. Once the piece starts to be coloured in red, stop the heating and remove it using the right
tool (clamp, spatter/wrench...) then remove it.
12

Publicité

Table des Matières
loading

Table des Matières