WIRING
WIRE THE OPERATOR(S) TO THE CONTROL
PANEL
1
Turn off the AC power from the main power source circuit breaker.
2
Insert the cables through a watertight connector mounted in the back of the
control panel.
3
Determine the open and close limit microswitch wires (Figure 1). Wire the
motor and microswitch wires as shown according to your application
(Figure 2).
4
Connect 120 Vac power to the power supply terminals on the electronic card,
50/60Hz frequency maximum.
5
Tighten watertight connector nut.
Do not apply AC power until instructed.
NOTE: The electronic card is equipped with an amperometric sensor which
constantly monitors the motor's drive. If the gate encounters an obstacle, the sensor
immediately detects the overload on the operator and the gate reverses.

WIRE THE OPERATOR(S) TO THE CONTROL PANEL

Figure 1
Left-Hand
Microswitch (Open Limit)
Motor Wires
Microswitch (Close Limit)
Figure 2: Single Gate Operator (Right-Hand)
120 Vac Power
Figure 2: Single Gate Operator (Left-Hand)
120 Vac Power
Figure 2: Dual Gate Operators
14
Right-Hand
Microswitch (Open Limit)
Microswitch (Close Limit)
2 (Brown Microswitch Wires)
FA1 Left Hand Operator
(Blue Microswitch Open
Limit Wire)
FA2 Right Hand Operator
(Blue Microswitch Open
FC1 Left Hand Operator
Limit Wire)
(Blue Microswitch Close
Limit Wire)
Motor Wires
FC2 Right Hand Operator
(Blue Microswitch Close
Limit Wire)