Malfunctions
Malfunctions
Error 3
No communi-
cation with the
mixer tap
Error 4
Error 5
Error 6
Error 7
Error 8
Error 9
Overheating
Possible causes
- Signal cable between the
mixer tap and carbonisa-
tion unit is not (correctly)
inserted
- Signal cable damaged
- Mixer tap control unit
damaged
- Appliance error
- Hardware error
- Component failure inside the
appliance
- Ambient temperature too
high
- Base cabinet not ventilated
Error correction
- Confirm the fault on the display by
pressing "OK"
- If this is not possible:
- Disconnect the power supply
- Check the plug connection of the signal cable
- Check the signal cable for damage
- Check the control unit for damage
- Reconnect the power supply after 5 minutes
- Confirm the fault on the display by
pressing "OK"
- Disconnect the power supply
- Reconnect the power supply after 5 minutes
- Confirm the fault on the display by
pressing "OK"
- Disconnect the power supply
- Ventilate base cabinet
- Leave the carbonisation unit to cool down
for 30 minutes
- Confirm the fault on the display by
pressing "OK"