PROBLEM
The machine does not start
when pressing the central
button.
The brush does not rotate.
Aspirator does not work.
The machine does not dry
well, leaving traces of water
on the floor.
TROUBLESHOOTING
CAUSE
Low battery (for BC version
only).
Plug disconnected (for E ver-
sion only).
Main fuse blown (for BC ver-
sion only).
Brush unit outlet overcurrent
error or brush unit open cir-
cuit error.
Brush motor damaged.
Brush rotation enabling but-
ton not pressed.
Suction unit outlet overcur-
rent error or suction unit
open circuit
error.
Intake motor damaged.
Aspirator enabling button not
pressed.
Aspirator off.
Aspiration tube blocked.
Squeegee rubbers not cor-
rectly set up.
Recovery tank full.
Squeegee
rubber
worn.
EN - 13
SOLUTION
Check that the battery is
charged.
Connect the plug.
Replace the GREEN 30A
main fuse.
See
paragraph
signals while using the ma-
chine".
Replace the ratiomotor.
Press the button.
See
paragraph
signals while using the ma-
chine".
Replace the turbine.
Press the button.
Start up the aspirator.
Check
and
clean the aspiration tube that
connects the squeegee to
the recovery tank.
Set up the squeegee rubbers
as indicated in paragraph
"Squeegee
Empty the recovery tank.
Replace or turn over the
blades
squeegee rubber blades.
"Warning
"Warning
if
necessary
setting".