PROBLEM
By pressing the button (45)
"
" ithe display does not
turn on.
The brush does not rotate.
Aspirator does not work.
No chemical product comes
out.
The machine does not dry
well, leaving traces of water
on the floor.

TROUBLESHOOTING

CAUSE
Low battery.
Main fuse blown.
The battery's plug is still lo-
cated in the charger's outlet.
Function card damaged.
Display card damaged.
Brush motor damaged.
Brush button not pressed.
Function card damaged.
Display card damaged.
Intake motor damaged.
Aspirator button not pressed.
Recovery tank full.
Blocked suction filter.
Function deactivated.
Empty tank.
Hose clogged.
Pump failure.
Flowmeter failure.
Control unit failure.
Suction motor defective.
Aspiration tube blocked.
Dirty wiper.
Recovery tank full.
Dirty water filter clogged.
Squeegee
rubber
worn.
ENGLISH - 20
Professional Cleaning Machines Since 1968
SOLUTION
Check that the battery is
charged.
Replace the main 5A or 80A fuse.
Place the plug correctly.
Replace.
Replace.
Replace.
Press the relative button.
Replace.
Replace.
Replace.
Press the button.
Empty, wash and clean the
tank and the probes.
Clean the filter.
Activate the function.
Replace.
Clean the tubes.
Replace.
Replace.
Replace.
Replace the motor.
Check
and
clean the aspiration tube that
connects the squeegee to
the recovery tank.
Clean the wiper.
Empty the recovery tank.
Clean the filter.
blades
Replace or turn over the
squeegee rubber blades.
www.ghibliwirbel.com