If a new OBJ is selected, TEST is automatically set on the maximum memorised number.
At this level it is possible to consult the entire result memory using keys
measurement values correspond to the OBJ: TEST selected is shown on the main display. It is
possible to scroll through them using the R-DAR-PI-DD key.
The V-TIME key is active and gives access to the date / time / U / OBJ-TEST number for each result.
If the recording selected by the OBJ : TEST number corresponds to a programmed-time test
the R (t) values can be accessed by pressing the R (t) key. The small display changes and indicates
st
min : sec (1
sample time) and the symbol flashes on the screen. You may use the
through the other samples.
To exit the R (t) mode and return to normal memory recall condition (OBJ : TEST), press the
R-DAR-PI-DD key again.
!
To exit the MR function, press again on MR or turn the switch.
6.3

Printing measured values (PRINT/PRINT MEM key) (C.A 6547)

If you use a serial printer, choose the appropriate communication speed, in the SET-UP menu, between
300...9600 bauds, then program the printer to the format controlled by the instrument (see § 6.1).
If you use a parallel printer, you must adjust the speed to «Parallel» in the SET-UP and use the series/
parallel adapter sold optionally (connect in series the cable delivered + adapter + Centronics printer
cable).
Two print modes are available:
- Immediate printing of the measurement (PRINT)
- Printing of memorised data ( PRINT memory )
If the transmission of data to the printer goes well, the COM symbol will flash on the display.
If a problem occurs, the COM symbol remains permanently displayed on the LCD screen.
6.3.1
Immediate printing of the measurement (PRINT key)
Following a measurement or after access to the MR mode (Memory Recall), the PRINT function is used
to print the measurement results.
As soon as the key is used, it prints:
- 1 group of measurements (U/R/DAR/PI/DD/date/time) in case of normal test,
- the R(t) values if the "Programmed time test"
To stop printing, change the position of the rotary switch.
Depending on the function used, the following models are obtained.
Insulation Measurements
CHAUVIN ARNOUX C.A 6547
Instrument number: 000 001
INSULATION RESISTANCE TEST
PURPOSE: 01
Description: ..................................................
.....................................................................
Date: .......................................... 31.03.1998
Starting time: ..................................... 14h55
Running time: ............. 15 min. 30 seconds.
Temperature: .............................. °C .........°F
Relative humidity: ..................................... %
function was activated.
TEST: 01
(printed only in MR mode)
54