Chamberlain HC250 Instructions page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INDEX
1.1 KIT CONTENTS
1.2 TECHNICAL FEATURES
1.3 HOW TO OPERATE THE DEVICE
1.4 SAFETY RECOMMENDATIONS
1.5 FOR HIGHER SAFETY
1.6 EMERGENCY CONTROL
1.7 COMPLIANCE TO NORMS
2.0 ACTUATORS ASSEMBLY TO PLATE
2.1 FRONT SUPPORT ASSEMBLY
2.2 SECOND ACTUATOR ASSEMBLY
3.0 WIRING
3.1 STANDARD ELECTRIC CONNECTIONS
3.2 SPECIAL CONNECTIONS
3.3 SETTINGS
3.4 SPECIAL ELECTRIC CONNECTIONS: PHOTOCELLS
3.5 EMERGENCY BATTERY
3.6 KEY SWITCH
3.7 FLASHING LAMP
3.8 TRANSMITTER ENCODING
4.0 CONTROL LIST
4.1 HELP ...TROUBLE SHOOTING
4.2 SPARE PARTS
4.3 ACCESSORIES
5.0 WARRANTY
1.1 CONTENT
• Actuators for right hand and left hand installation
• Electronic control with radio receiver
• 3-channel transmitter
• Flashing lamp
• Adjustable mounting brackets
• Manual
1.2 TECHNICAL FEATURES
A. Actuators
• 12V d.c. Motor
• Maximum thrust: 150N on the closing edge
• Piston rod speed: 1.5cm per sec.
• Possibility of continuous work (for a short period of time)
• Operating temperature: -15
0
• Protection degree: IP44
B. Electronic control
• Plastic housing with IP44 protection degree, provided with No. 3+2
fairleads
• Control card
• 40 amp. relays
• 12V a.c. power supply input; 12 V d.c. outputs
• Double working program: Manual/Automatic
• Power supply warning LED
• Toroidal transformer - CE - 230/120V 50/60Hz 12V 100W
C: Transmitter
433.92MHz quartz transmitter in compliance with norms
I-ETS 300 220, PPT approved.
D: Keyswitch (not included)
E: Flashing lamp
• Plastic housing with IP44 protection degree provided with fairlead
• Lamp holder
• 12V 10W max. bulb
F - L: Adjustable Fixation system
I: Unlocking key
M: Pair of 12V photocells
N: Antenna with cable
to +45
0
1.3 HOW TO OPERATE THE DEVICE
The pulse is sent to the remote control and is received by the
electronic programmer which provides to supply the energy to motors
which drive the gate wings. A second pulse will provide for the wings
closing. By adequately programming the equipment, one is able to
make the wings close automatically. The Flashing lamp will warn the
wings are moving. The system is designed to last many years and NO
MAINTENANCE is needed.
At intervals wash the actuators with water and soap.
The actuator piston rod made of stainless steel has NEVER to be
lubricated.
1.4 SAFETY ADVISES
The system is provided with a crushing-proof electronic safety device
controlled by microprocessor. Check the perfect alignment of the gate
hinge pivots for a correct adjustment. The gate mutst be in proper
working condition in order to function correctly with the opener. A gate
stop is necessary for both the open and closed postitions.
1.5 FOR HIGHER SAFETY
We advise to install one or two pair of photocells. They shall provide
for the reopening of the wings in case an object obstructs their way.
We also advise to comply with norms concerning automation in force
in the various countries (refer to 1.7 Compliance to norms).
1.6 EMERGENCY CONTROL
In case the system fails, the gate can be manually opened.
Insert the triangular key inside the triangular plug placed over the
motors, then turn counter-clockwise till the stop. Motors shall unlock.
The inverse operation restores the gate automation.
1.7 COMPLIANCE TO NORMS
The equipment is in compliance with EEC directives: EEC 89/392
Fig. 1
EN61000-3-2 EN61000-3-3. EN55014 ETS 300 683 ENV 50141.
1-ETS 300-220 CEPT T/R 01-04. Class II equipment.
EEC 72/23 EN60335/1, EN60529/II, EN60034.
TÜV GS APPROVAL.
2.0 ACTUATORS ASSEMBLY TO PLATE
Assemble the adjustable plate and fix it to the wall.
Fig. 1
This operation is extremely important as it shall determine the
following parameters:
1. Gate opening speed
2. Actuator thrust strength
Fundamental elements to make this choice are the following:
1. The gate size (weight/length)
2. Pillar size
You will find a series of sizes to determine the positioning of plate with
respect to the gate rotation axis (hinge pivot) (Fig. 6).
For gate whose length is longer than 150cm, consider "B" measures
higher than 10cm (Fig. 7 - B is more than 10cm).
Some standard advised measures are:
Gates not exceeding 150cm.
A = 10cm / B = 10cm
Gates exceeding 150 - 200cm
A = 14cm / B = 12cm
Remind the higher is "B" measure, the slower the gate will open.
Figure 7: Maximum thrust strength allowed: 150N
In order to be sure not to exceed 15kg of thrust strength, do NOT use
measures shown in the blackened boxes of Fig. 7. In case it were
necessary to use those measures, it is compulsory to install a double
pair of safety photocells.
1-GB
Fig. 2
Fig. 14
Fig. 16 & 17
Fig. 3
Fig. 4-7

Publicité

Table des Matières
loading

Table des Matières