6. Door does not close completely:
Adjust the Close Limit.
Repeat safety reverse test after any adjustment of door arm length, or Close
Limit.
7. Door opens but won't close:
Check The Protector System™ (if you have installed this accessory). If the light
is blinking, correct alignment.
Repeat the safety reverse test after the adjustment is complete.
8. Opener light does not turn on:
Replace light bulb (21 Watts maximum).
9. Opener light does not turn off:
Defective logic board.
10. Opener motor hums briefly, then won't work:
Garage door springs are broken. Close door and use Manual Release Rope
and handle to disconnect Trolley. Open and close door manually. A properly
balanced door will stay in any point of travel while being supported entirely by
its springs. If it does not, call for a professional garage door service to correct
the problem.
If problem occurs on first operation at opener, door may be locked. Disable
door lock.
11. Opener won't activate due to power failure:
Pull Manual Release Handle to disconnect Trolley. Door can be opened and
closed manually. The next time opener is activated, the Trolley will reconnect.
The Outside Quick Release accessory (if fitted) disconnects the Trolley from
outside the garage in case of power failure.
22
Wiring the Lighted Door Control Button
(Optional)
Locate any Wall Mounted Door Control where the garage door is visible, away
from door and door hardware, at a minimum height of 1.5m. fasten the child
warning label on the wall near the Door Control.
There are 2 screw terminals (1) on the back of the Door Control (2). Strip about
6mm of insulation from bell wire (4). Separate wires enough to connect the white/red
wire to terminal screw 1 and the white wire to terminal screw (1).
Lighted Door Control Button: Fasten to an inside garage wall with sheet metal
screws (3) provided with Lighted Push Button. Drill 4mm holes and use anchors (6)
if installing into drywall or concrete. A convenient place is beside the service door
and out of reach of children.
Run the bell wire up the wall and across the ceiling to the garage door opener. Use
insulated staples (5) to secure wire.
The opener Quick-Connect Terminals (7) are located in the recess next to the learn
button on the left side panel. Insert bell wire into holes in the Quick Connect
Terminals as follows: Red/White to Red and White to White.
23
Install the Outside Quick Release
Note: The steel cable must not be taut, because the distance is reduced when the
door is open.
1. Thread the steel cable through the appropriate hole in the release lever. (fig. 23b)
2. Mount top and bottom mountig plates. To mount the top plate, use screw of door
arm connection. (fig. 23 b+d)
3. Drill holes in the handle extension (20mm distance)and screw it in place. (fig.
23d)
4. Attach sleeve on bowden wire. (fig. 23a)
5. Thread bowden cable, cut if necessary.
6. Thread steel cable completely.
7. Attach nipple on bottom end of steel cable. (fig.23d)
8. Test the adjustment and mount the cable binder. (fig.23a)
114A3360B - GB
24

Replacement Parts/Accessories

(1)
04665
(2)
04765
(3)
03465
(4)
41B0668
(5)
09660
(6)
05765
(7)
06765
(8)
HE4331
(9)
HE1702
(10)
HE75
Specifications
Input Voltage . . . . . . . . . . . . . . .230 VAC 50/60 Hz
Max. Pull force . . . . . . . . . . . . . .600N
Rated Power Input . . . . . . . . . . .85 Watts
Rated Load . . . . . . . . . . . . . . . .3.0 Nm
Standby Power . . . . . . . . . . . . . .9 Watts
Max. Door Weight . . . . . . . . . . .60kg
Motor
Type . . . . . . . . . . . . . . . . . . . . . .63:1 Worm Gear Reduction
Volts . . . . . . . . . . . . . . . . . . . . . .24VDC
Drive Mechanism
Length of Travel . . . . . . . . . . . . .2.3M
Travel Rate . . . . . . . . . . . . . . . .8cm/sec
Lamp . . . . . . . . . . . . . . . . . . . . .24V 21 Watts
Safety
Electronic . . . . . . . . . . . . . . . . . .Auto-Force Adjustment
Electrical . . . . . . . . . . . . . . . . . .Thermal Fuse in Transformer
Limit Adjustment . . . . . . . . . . . . .Manual
Dimension
Length (Overall) . . . . . . . . . . . . .2,75m
Headroom Required . . . . . . . . . .30mm
Hanging Weight . . . . . . . . . . . . .9kg
Receiver Code Registers
Billion Code . . . . . . . . . . . . . . . .12
Dip Switch . . . . . . . . . . . . . . . . .1
Keypad . . . . . . . . . . . . . . . . . . . .1
Operating Frequency . . . . . . . . .433.92MHz