8. Troubleshooting

0.1 Battery-operated clipping machine Econom CL/Econom CL Equipe/Econom CL Fitter
Malfunction
The battery-operated clipping machine
does not start
The battery-operated clipping machine
pauses during operation
Detection
The LED of the on/off button 36
blinks twice per second
Cause
Li-ion battery not activated
Li-ion battery not loaded
Li-ion battery defect
Li-ion battery not inserted
Li-ion battery deactivated through
protective circuit
Li-ion battery is empty
Remedy
Press button e on the lithium ion
battery
Load Li-ion battery
Insert new Li-ion battery
Insert the Li-ion battery
Switch the battery-operated
clipping machine off and on again
Insert new Li-ion battery