12. INSTALL THE ROUGH-IN PLATE FOR EXTERNAL BLOWER (CP47E SERIES ONLY)
Refer to the instructions included with the selected blower/rough-in kit (sold
separately) for details on installing the rough-in plate. Install the rough-in plate so
that the wiring box is located on the right side when facing the hood, as specified
on the blower housing label.

13. CONNECT WIRING (ALL BLOWERS)

Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally.
Position the power pack below the installed custom hood.
INTERNAL BLOWERS: Insert the house wiring cable through the wire clamp
previously installed in step 8. Tighten the wire clamp to
secure the cable. Connect cable into wiring box using
wire connectors. Connect BLACK to BLACK, WHITE to
WHITE and GREEN or bare wire under GREEN ground
screw. DO NOT FORGET TO CONNECT THE GROUND.
Reinstall wiring box cover.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
14. REMOVE THE INTERNAL BLOWER(S) (CP45I AND CP47I SERIES ONLY)
In order to ease the power pack alignment with existing ductwork, unplug and disassemble the blower(s) from the power pack before
installing the custom hood.
A
I
B
M
LL
NTERNAL
LOWER
Unplug the blower(s)
ODELS
HE0085
HD0333
WARNING
!
HE0059
9
W
IRING BOX
COVER
L
OCK NUTS