12. REMOVE THE INTERNAL BLOWER(S) (CP45I AND CP47I SERIES ONLY) (
S
B
M
INGLE
LOWER
ODELS
Using a 5/16" socket, a Robertson or a Phillips
no. 2 screwdriver, remove all blower mounting
screws from the inner top of the power pack. Set
the screws aside.
Slide the blower to disengage its flange from the
retaining bracket. Set the blower aside.
D
B
M
UAL
LOWER
ODELS
For each blower, using a 5/16" socket, a Robertson or a Phillips no. 2 screwdriver, remove all blower
mounting screws from the inner top of the power pack front and rear brackets. Set the screws aside.
For each blower, slide it to disengage its flanges from the retaining brackets. Set the blowers aside.
15. INSTALL POWER PACK
MODEL CP45I ONLY: If the model CP45I is to be installed with a non-duct kit, install a 8" to 7" reducer (included in non-duct kit) prior to
install the power pack in its custom hood.
Take care not to kink ducting when installing the power pack.
Using provided no. 8 x 1/2" chrome plated screws, install the power pack inside the
custom hood. Start with 2 screws on front corners, then use 4 screws for sides and use
the remaining screws to finalize securing the front power pack. (See figure at right for
mounting screw specific locations.)
Make sure the adapter/damper (or the adapter) enters the ducting. When there is
access to the top of the power pack, seal connections with metal foil duct tape.
HD0269
HD0270
CAUTION
L
EFT SIDE MOUNTING
SCREW LOCATIONS
10
CONT
R
IGHT SIDE
MOUNTING SCREW
LOCATION
HD0282
B
LOWERS FRONT BRACKET
B
LOWERS REAR BRACKET
HD0297
HD0298
HH0102A
'
)
D