Robert Juliat CYRANO 1015 Dossier Technique page 24

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
CONDENSER.
- Disconnect from the mains.
- Open the lamp house's bonnet.
- Take out the lamp.
( Refer to section A - 11 and proceed in reverse order).
- Turn the fast lock 1 .
- Withdraw the lens holder 2 .
- Clean the lens 3 with a soft dry cloth.
- Remount parts in reverse order.
- Clean in the same way, the 2 lenses found in the lens tube.
MIRROR.
- Disconnect from the mains.
- Open the lamp house's bonnet.
- Take out the lamp.
( Refer to section A - 11 and proceed in reverse order).
- Clean the mirror 4 with a soft dry cloth.
- Remount parts in reverse order.
SPARK-GAP.
- Disconnect from the mains.
- Open the lamp house bonnet.
- Check the distance of the electrodes that should be 1mm.
(If you notice a larger gap, then please contact the ROBERT JULIAT's
technical department).
service@robertjuliat.fr
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W HMI FOLLOWSPOT
Disconnect from the mains before any servicing.
Service only by qualified technician.
1015 /
B, BS, M & BSM
Section B - 1
1 mm