PUTTING THE LAMP INTO PLACE.
User's instructions :
- Make sure the voltage is turned off.
- Lamp is cold.
- Avoid touching the bulb of the lamp.
MOUNTING THE HEATSINK ONTO THE BASES :
- Make sure that the guard rings a are well
placed on the neck of the heatsinks 1 .
1
PREPARATION OF THE JAW SOCKET :
2
3
- Raise the deflector plate.
- Unscrew the nuts 4 and raise the jaws 2 to the top of the shunks 5 .
- Turn the jaws 2 socket 90° to the exterior and place them onto the corner plates 3 .
POSITIONING THE LAMP :
9
6
SIDE VIEW
10
- Position the lamp into place.
- Check that the heatsinks 1 are placed to the exterior of the isolating plates 7 .
- Place the jaws 2 onto the neck of the heatsinks.
- Make sure the necks of the heatsinks are placed well in the top and bottom jaws,
check by moving the mobile jaw 6 with the help of the lever 10 .
- Place the slots of the heatsinks horizontally 11 .
- Place the closing point of the lamp 9 upwards.
- Tighten the 2 nuts 4 with a 6 sided bolt-driver N° 13 8 and make sure you stay in axe 12 .
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
2500W HMI FOLLOWSPOT
Base : SFa 21 - 12
OVERHEAD VIEW
7
1
2
9
OVERHEAD VIEW
TECHNICAL FILE
150
2
3
5
1
2
6
FRONT VIEW
12
!
1015 /
B, BS, M & BSM
Section A - 11
a
1
1
4
2
3
5
12
SIDE VIEW
8
10
11
SIDE VIEW
!
4
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cyrano 1015 bCyrano 1015 bsCyrano 1015 mCyrano 1015 bsmCyrano1015 ... Afficher tout

Table des Matières