Robert Juliat CYRANO 1015 Dossier Technique page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTIONS.
Mains voltage.
- Check the conformity of the mains voltage input with the values indicated
on the identification plate of the PSU (mains voltage & lamp power)
Rating plate 6 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable C to the connector 5 of the
ballast and connector d to the lighting unit.
- Lock the cable C into the cable lock e .
- Place the lamp into position - refer to section A - 11.
- Engage the circuit breaker 3 and check that the protection
4 is well engaged.
- Plug the cable 7 to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the circuit breaker 2 .
WARNING !
- Never open the lamp house's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W HMI FOLLOWSPOT
A
d
e
C
B
5
4
1 2 3
6
7
• Use only the listed cables to connect to the mains -
Refer to the respective PSU technical fi le.
DESCRIPTION.
A 1015 / BS - Manual shutter version.
d - EM HARTING 16 x 16A power socket.
B Power supply unit.
C Lamp cable.
Cable H07 RN-F 18G 1,5 mm
with 16 x 16A M/F HARTING connectors.
1015 /
1015
B, BS, M & BSM
Section A - 5
Power supply unit
(P.S.U.)
2
length 3m fitted

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cyrano 1015 bCyrano 1015 bsCyrano 1015 mCyrano 1015 bsmCyrano1015 ... Afficher tout

Table des Matières