Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
The device must be installed in the rooms adapted for combustion gas extraction.
The installation must be realized according to the valid standards.
The devices belong to the following category:
Devices supplied with gas of category A and are not designed
for connecting to the combustion gas extraction system.
The combustion gas produced by the devices must be removed with use of
appropriate hoods or other similar devices connected to efficient chimney stack or
directly outside.
If there are no such devices the fan may be used for extracting the combustion gas
directly outside of power not lower than the recommended values.
Before positioning the device check the dimensions and exact positions of the
electric and gas connections.
Locate the device in a safe place, on a level surface capable of supporting the device's
weight with the maximum amount of food products.
Never place the device on a flammable surface or one sensitive to high temperatures.
Do not place the device near open flames, electric heaters or other heat sources.
Never place the device directly next to walls, furniture or other objects made of
flammable materials. Keep a minimum distance of 200 mm from the sides and rear.
Keep a minimum distance of 600 mm between the upper surface of the device and
surfaces located above it. Proceed according to relevant fire safety regulations.
If it is not possible to observe the above distances, apply protective measures
(e.g. heat-resistant coatings) that can resist temperatures of at least 65 ° C .
Use only original spare parts!
Regulate the level and height of the device with the adjustable legs. Large differences
in height or level may have a negative impact on the device's functioning.

5.1.2 Electric connection

DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid specification
should be compared with that of the device (see rating plate).
Connect the device only in case of compliance!
- 45 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mfgo 7060Mfg 7360158200115821011582201

Table des Matières