In the event of deviations from the values given above, proper functioning of the
device is not guaranteed.
Table 2 Nozzle and burner properties (GB, IE, GR - CAT. II
Gas type
pressure
(mbar)
G20
G30/G31
28-30/37
G20
G30/G31
28-30/37
Categories
II
2L3B/P
II
2H3B/P
II
2WLwLs3B/P
II
2H3+
II
2H3B/P
II
2H3B/P
II
2H3B/P
II
2H3+
II
2H3B/P
II
2H3+
II
2H3B/P
II
2H3B/P
II
2H3+
Gas
Nozzle
min/max
Burner 3.5 kW
20
140
92
Burner 6.0 kW
20
185
120
Gas type
G25 - G30/G31
G20 - G30/G31
G20/G27
G2.350
G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
G20 - G30/G31
Setting for
primary air
burner nozzle
(mm)
6
8
4
15
Gas pressure
(mbar)
25 - 30/30
20 - 30/30
20/20
13
37/37
20 - 28-30/37
20 - 30/30
20 - 30/30
20 - 30/30
20 - 28-30/37
20 - 30/30
20 - 28-30/37
20 - 50/50
20 - 30/30
20 - 28-30/37
)
2H3+
Ignition
Bypass
nozzle
35
adjustable
20
50
35
adjustable
20
62
- 43 -