Connect the power supply terminal J1 to the electric
network using a suitably sectioned cable.
All the conductors of terminals MAIN-IN,
HH-PUMP and WIPER must be separated
from the other low voltage circuits.
The disconnection of a wire must not
compromise the protection against electric
shocks.
6.1.5 Pump installation
Be very careful not to start the pump when
the tank is empty.
6.1.5.1 Pump with 5m (16ft) delivery
Fill the tank with water and insert it in the metal cage.
Insert the pump in the tank and tighten the cap.
The system is ready to be powered.
6.1.5.2 Pump with 11m (36ft) delivery
Adjust the position of the level controller and the
weight.
Fig. 10
Fill the tank with water and insert it in the metal cage.
Put the pump and float inside the tank and screw the
plug on.
The system is ready to be powered.
MNVKWASPT_1426_EN
220mm
120mm
6.1.5.3 Pump with 30m (98ft) delivery
Avoid contact. Surfaces are hot and may
cause personal injury if touched.
Adjust the position of the level controller and the
weight.
Fig. 11
Fill the tank with water and insert it in the metal
cage, taking care to insert the male/female hydraulic
coupling (01) correctly. Put the float inside the tank
and screw the plug on. Check the delivery hose
coupling for the pump (02) to make sure a small
quantity of water comes out.
01
Fig. 12
Connect the supply pipe.
The system is ready to be powered.
220mm
120mm
02