7 Maintaining and cleaning
7.1 Maintaining
7.1.1 Fuses replacement
7.1.1.1 Replacing the fuse of the pump
board
The used fuse is described below.
• T 4A H 250V: BUSSMANN S505-4-R/OMEGA
GT520240
As an alternative, use an approved fuse featuring the
same characteristics.
For further information refer to the relative
chapter (6.1.4.1 Installing the fuse, page 5).
7.1.1.2 Replacing the fuse on the pump inlet
The used fuses are described below.
Pump with 5m (16ft) delivery:
• T 2A L 250V: BUSSMANN S506-2-R/OMEGA
ST522220
Pump with 11m (36ft) delivery:
• T 4A L 250V: BUSSMANN S506-4-R/OMEGA
ST522240
As an alternative, use an approved fuse featuring the
same characteristics.
Once the box is open identify the fuse position.
Fig. 22
Check the causes that caused the fuse breakage.
In the event the problem occurs again, contact the
technical assistance service.