6.1.4.1 Installing the fuse
Move the fuse into the correct fuse holder
according to the input voltage.
230V
FUS1
Fig. 6
The board is supplied with the fuse in position FUS1
(for a 230Vac power supply).
If the power supply is different position the fuse
correctly referring to the following table.
INSTALLING THE FUSE
Voltage
230Vac
120Vac
24Vac
Tab. 1
MNVKWASPT_1426_EN
120V
24V
FUS2
FUS3
Fuse holder
Fuse in FUS1
Fuse in FUS2
Fuse in FUS3
6.1.4.2 Pump and alarms connection
All the connections of terminal J9 must
have very low safety voltage.
Connect the Pan & Tilt to the J9 terminal contacts as
described in the table below.
Fig. 7
The AVL, GND, A1L and A2L contacts can
only be used in pump models equipped
with floats.
PUMP AND ALARMS CONNECTION
Terminal
Description
CP
Pump control O1
GCP
GND (pump
control)
AVL
Float alarm
GND
GND (float
alarm)
A1L
Float alarm
(clean con-
tact)
A2L
Float alarm
(clean con-
tact)
Tab. 2
The pump can be switched on manually
(without using the pan & tilt) using the
CP and GCP dry contacts. This solution is
particularly suitable when washing the
housing windows.
J9
A B
RS485
ULISSE
ULISSE
COMPACT
R2A
C1
R2B
AL1
W
COM/AGND
G
Alarm 1 (only
for ULISSE
NETCAM
family)
ALARMS (only
for ULISSE
NETCAM
family)
5