Airless and Multi Spray iCon Pumps
Inconvenience
4. The pump does not
stop.
5. The spray-fan size
keeps changing
6.The indicator of
pressure gauge indicates
the presence of pressure
even though the air
regulator is closed.
22
Cause
c) Seats and balls (inside the fluid
pump) are dirty or damaged.
d) The V-packings (inside the fluid
pump) are dirty or damaged.
e) Leakage from the paint ducts.
f) The drain valve is not closed.
a) The V-packings (inside the
fluid pump) are dirty or damaged.
b) Seat and ball (inside the fluid
pump) are dirty or damaged.
c) Spray gun nozzle, worn out.
d) Paint filter of paint circuit
clogged.
a) Damaged air regulator.
Check
c) Disassemble the fluid pump and
check the seat and ball conditions.
d) Disassemble the fluid pump and
check the V-packings conditions.
e) Inspect all the paint ducts.
a) The pump does not stop.
b) The pump does not stop.
Solution
c) Clean them if they are enclosed
with solidified paint residues.
Otherwise, if they are irreparably
worn out, replace them.
*Refer to fluid pump instruction
manual.
d) If it is enough, adjust them.
If they are irreparably worn out,
replace them.
*Refer to fluid pump instruction
manual.
e) If any leakage is found, see to its
fixing.
f) Close the drain valve.
a) If it is enough, adjust them.
If they are irreparably worn out,
replace them.
*Refer to fluid pump instruction
manual.
b) Clean them if they are enclosed
with solidified paint residues.
Otherwise, if they are irreparably
worn out, replace them.
*Refer to fluid pump instruction
manual.
c) Replace it. *Refer to the instruction
manual of spray gun.
d) Refer to (2 - a).
a) Replace it.