7 PC Control of the Unit via RS-232 Interface
It is possible to control the CD-112RDS / BT from
a PC via a suitable terminal program. Connect
the jack REMOTE CONTROL (32) to the RS-232
interface of the computer. Set the following
parameters in the terminal program:
Symbol rate . . . . . . . . . 9600 bauds
Number of data bits: . . 8
Number of stop bits: . . . 1
Parity: . . . . . . . . . . . . . . none
Flow control: . . . . . . . . none
The control commands for all functions of the
CD-112RDS / BT are listed in the tables below.
The terminal program will send them in ASCII
code. Finally, the commands "Carriage Return"
(0D hexadecimal) and "Line Feed" (0A hexadec-
imal) must be sent to the CD-112RDS / BT as
bytes 4 and 5. Some terminal programs will exe-
cute them automatically or can be adjusted
accordingly.
Functions of the CD/ MP3 player
Control command
Function
Byte 1
E
FOLDER
FOLDER
E
E
SKIP REV
E
SKIP CUE
STOP
E
PLAY/ PAUSE
E
EJECT
E
PROG
E
ESP
E
FIND
E
MUTE
E
REPEAT
E
FUNC
E
DISPLAY
E
disable EJECT
E
enable EJECT
E
0
E
1
E
2
E
3
E
4
E
5
E
6
E
7
E
8
E
9
E
After a command has been executed, the CD-
112RDS / BT will send the following message in
ASCII code to the PC:
+ O K "Carriage Return" "Line Feed"
In case of an input error, it will send the mes-
sage:
+ E R "Carriage Return" "Line Feed"
Note: Between two commands, there must be an inter-
val of at least 300 ms. After a command for station scan-
ning, an interval of at least 800 ms is required.
Functions of the tuner
Function
Byte 2
Byte 3
A
A
1
2
A
B
A
C
3
A
D
4
5
A
E
A
F
6
A
G
7
A
H
8
A
I
9
10 / 0
A
J
A
K
+10
A
L
DIRECT
(TUNING) DOWN
A
M
A
N
(TUNING) UP
A
P
(STATION) M-UP
(STATION) M-DOWN
A
Q
A
0
MEMORY (MEM)
A
1
ASM
MO/ ST
A
2
A
3
SLEEP
A
4
Station scanning
A
5
Station scanning
A
6
A
7
A
8
A
9
All rights reserved by MONACOR
manual may be reproduced in any form or by any means for any commercial use.
8 Maintenance
Protect the unit from dust, vibrations, humidity
and heat (admissible ambient temperature
range 0 – 40 °C). For cleaning only use a dry,
soft cloth; never use water or chemicals.
Note concerning sound interruptions and
reading errors
Cigarette smoke and dust will easily penetrate
through all openings of the unit and will also set-
tle on the optics of the laser sampling systems. If
this deposit should cause reading errors and
sound interruptions, the unit must be cleaned by
skilled personnel. Please note that there will be
a charge on cleaning, even during the warranty
period!
9 Specifications
CD / MP3 player
Frequency range: . . . . . . 20 – 20 000 Hz
THD: . . . . . . . . . . . . . . . . < 0.1 %
Channel separation: . . . . > 60 dB
Control command
Byte 1
Byte 2
Byte 3
Dynamic range: . . . . . . . . > 96 dB
E
C
A
S / N ratio: . . . . . . . . . . . . . > 70 dB
E
C
B
Audio output: . . . . . . . . . . 1.2 V
E
C
C
E
C
D
Tuner
E
C
E
E
C
F
Received frequency: . . . . 87.5 – 108 MHz
E
C
G
E
C
H
General information
E
C
I
Power supply: . . . . . . . . . 230 V~ / 50 Hz
E
C
J
Power consumption: . . . . 50 VA max.
E
C
K
E
C
L
Ambient temperature: . . . 0 – 40 °C
E
C
M
Dimensions (W × H × D): . 482 × 44 × 265 mm,
E
C
N
E
C
0
Weight: . . . . . . . . . . . . . . 4.1 kg
E
C
1
E
C
2
E
C
3
E
C
4
E
C
5
E
C
7
Subject to technical modification.
E
C
8
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction
GB
1 rack space
13

Publicité

Table des Matières
loading

Table des Matières