AXIS conversion kit
04.
Checking the metering slide adjustment
Requirements:
• The mechanical system can be moved freely.
• The return spring is unhooked.
• The hydraulic cylinder is unhooked.
04.1. Set the stop lever to the value
"85", secure it using the T-handle
and manually pull the metering
slide to the end stop.
The figure shows AXIS 30/40.
04.2. Insert a lower link pin d = 28 mm
centrally into the metering
opening.