GUDEL ZP 3-5 V4 Mode D'emploi page 102

Table des Matières

Publicité

Mise en service
Fig. 7-28
Formule de calcul cote X
102
X = Z – Y
Dimen-
Type
sion uni-
d'accou-
té réduc-
plement
teur
Güdel
HPG
030
GWE
5103-19-
SP
GWE
5103-14-
SP
045
GWE
5103-24-
SP
GWE
5103-19-
SP
060
GWE
5103-28-
SP
GWE
5103-24-
SP
090
GWE
5103-38-
SP
GWE
5103-28-
SP
Cote L
Tolé-
[mm]
rance
cote L
[mm]
50
+1
+0.5
32
+1
+0.5
54
+1
+0.5
50
+1
+0.5
62
+1
+0.5
54
+1
+0.5
76
+1.2
+0.5
62
+1
+0.5
MODE D'EMPLOI ZP 3-5 V4
Cote Y
Tolé-
[mm]
rance
cote X
[mm]
8.5
+0.5
-1
15.5
+0.5
0
11
+0.5
0
10
+0.5
0
16.5
+1
-3
18.5
+1
-2
25
+1
-2
29
+1
-2

Publicité

Table des Matières
loading

Table des Matières