SURFACE MOUNTING

All parts required for surface mounting are included in the optional Surface Mount Kit (see page 4). These instructions are for surface
mounting. Refer to page 6 for door removal instructions.
1. It is strongly recommended that the wall be framed behind the drywall or tile.
2. Electrical field wiring: Electrical feed through location is indicated below. See page 5 for wire access locations.
NOTE: Make sure cabinet door has at least 1" (25mm) clearance above the top of the faucet (including drain stop) and at least 1" below
the ceiling.
1
2
1" (25.4 mm)
Minimum from finished ceiling
C
B
Field Wiring
A
B
C
YC24
9-1/2"
5-3/4"
14-3/8"
A
Cabinet
(248 mm)
(146 mm)
(365 mm)
1" (25.4 mm)
Minimum door to faucet
WARNING: An Electrical option cabinet must be wired to a Class A 20 Amp GFCI (Ground Fault Circuit Interrupter) protected circuit
when used in bathrooms and all other locations required by the National Electric Code.
Part no. CB-209-1332 05/05/20
Vitality Cabinet
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
12
Installation instructions