Tylo CC300 Mode D'emploi page 5

Masquer les pouces Voir aussi pour CC300:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
INSTALLATION CC300
Please read these instructions together with the installation
instructions supplied with the sauna heater or steam generator.
Relay box (RB).
(No relay box is needed with Tylö SE sauna heaters).
Install outside the Tylarium and at any distance from the Tylarium in a
cool, well-ventilated room. Important! Always ensure a minimum distance
of at least 1 metre between the relay box and the CC300.
Shielded low-current cable (LiYCY 6-core).
Use only a shielded low-current cable (LiYCY, 6-core) between the
CC300 and the relay box, SE sauna heater or steam generator. Connect
the shielding to terminal 12 on the CC panel.
Location of thermistor, humidity/temperature sensor.
Install 1500 mm above floor level (but not directly above a sauna heater).
Place the sensor so that it does not risk being affected directly or indirectly
by a jet of steam. The thermistor wire can be extended outside of the cabin
with a shielded low-voltage cable (2-core).
Lighting.
Connect the lighting as indicated in the wiring diagram.
Optional external on/off-switch (quick-break).
May be placed at any distance from the CC300. Connect to the CC300
using a low-current cable – see wiring diagram. If more than one external
on/off switch is used, the switches must be connected in parallel. Press
once on the external switch to start the CC300, which then remains in
operation for as long as the running time has been set. (See 'Initial start-
up'.) The next time you press the external switch, this will turn off the
CC300 – unless it has been pre-programmed or is protected by a
security code. If the CC300 has been pre-programmed or is protected by
a security code, it must be switched off by pressing the ON/OFF button
on the control panel.
Optional external on/off-switch (maintained contact).
May be placed at any distance from the CC300. Connect to the CC300
using a low-current cable – see wiring diagram. If more than one external
on/off switch is used, the switches must be connected in parallel. When
connected to receive a constant signal, the facility remains operational
for as long as contact closure is maintained between terminals 19 and
20, but only up to the maximum running time that has been set.
Connection to a central computer.
The unit can also be connected to a central computer that transmits a
momentary contact closure (short impulse) or constant signal between
terminals 19 and 20 in the CC 300. The maximum permissible running
time is 24 hours.
Important! In order for the steam generator's automatic emptying
function to work, the control panel must be switched off for at least 1.5
hours each day.
Controlling other Tylö products.
The CC300 can also be used to control other Tylö products, such as a
Tylö Fresh fragrance dispenser, which can be activated while the panel is
in operation. Wiring for Tylö Fresh or other CC-panels must be
connected between terminals 40 and 41 on the CC 300 and terminals 19
and 20 on the other Tylö product.
OPERATING INSTRUCTIONS
CC300
4
1
Fig. 1. Menu display
1 = Left button, 2 = Middle button, 3 = Right button. 4 = Symbols/text that
correspond to the respective button. 5 = Symbols/text for setting and
displaying current values.
Buttons and display.
There are three buttons on the control panel. Symbols shown above the
buttons at the bottom of the display correspond to the respective button.
These symbols differ depending on the panel's current mode. When the
arrows are shown in the Menu display (fig. 1), use the left and right
buttons to move to the desired symbol. To select a symbol, confirm with
the middle button.
In the Normal display (fig. 2) the left button has an ON/OFF function. The
symbol for this appears at the bottom of the display above the left button.
When the facility is operational, this symbol shows green; when it is
switched off, the symbol is red; and when it is on stand-by, the symbol is
orange. The right button controls the lighting function. The lighting
symbol shows yellow when the lighting is on and white when the lighting
is off. The display also shows the current temperature.
To return to the Normal display from another mode, press the middle
button until the Normal display shows.
When a program is active, press the left button for 2 seconds to switch
off the active program.
Fig. 2. Normal display
Initial start-up.
When you switch on the control panel for the first time, you must
configure certain basic settings. First select the relevant region and
confirm your choice by pressing the middle button. Then select the
desired language and confirm with the middle button. Next, use the left
and right buttons to set the correct date and time, and confirm with the
middle button. Finally, set the running time for a manually activated
bathing cycle. (The standard setting is for 3 hours, but you can choose
1–24 hours.) Move up/down with the right/left button respectively until the
OK
R
2
3
5
ºc
22
MENU
R
5

Publicité

Table des Matières
loading

Table des Matières